Energy efficiency standards for lighting products in saudi arabia updated.1, Street lights SASO 2927:2019-AMD 1:2021(1) The requirements of clause 10.3 electrical parameters have been changed:
The operating voltage of the control device is 120-277, 60Hz; the operating voltage of the control device is changed to include the Saudi standard voltage of 230V, 60Hz.
2, light source SASO 2870:2018-AMD 1:2021
- Delete some reference standards, the details are as follows:
a, SASO GSO IEC (60432-1)Tungsten Safety Standard.
b, SASO 1983 IEC (60432-2)T-H Safety Standard.
c, SASO 2570 IEC (60432-3)T-H Safety Standard.
d, SASO GSO IEC 60968 CFLi Safety Standard.
e, SASO 2720( IEC 61199)Single-capped fluorescent lamps Safety Standard.
f, SASO IEC IEC 62471 Photo biological Safety of lamps and Lamp Systems.
g, SASO IEC IEC 62560 Self ballasted LED lamps>50V Safety Standard.
h, SASO Standard to be adopted based on(project IEC 62663-1) Non-ballasted LED lamps- Safety Standard.
i, SASO Standard to be adopted based on(project IEC/PAS 62838) safety of LED lamps with supply voltages smaller equal 50V.
j,SASO IEC/PAS 62868 safety of OLED.
(2) Clause 4.1 of energy efficiency requirements is added:When registering, it is allowed to use the same test report in the SLS system for models with only different color temperatures and the same product technical indicators.
(3) The marking clause 4.3 requires a change:For special-purpose lamps, it is necessary to reflect on the packaging:
Trademark, model name, rated power, rated voltage, rated luminous flux, rated color temperature, place of origin, use.
(
4) The ANNEX E mark has been changed:Nominal power is changed to Rated power (Watt).
(5) Packaging changed:Added on the original basis: rated power factor, rated CRI.
(6) Label design has changed: If the package is less than 43mm wide/45mm high, the energy efficiency label will be reduced and placed on the package; public account: Shenzhen LED Network
In addition, when registering, there will be an independent QR code, and the QR code will be printed on the packaging.
3. Light sources, lamps, and drivers SASO 2902:2018-AMD 1:2021 (mandatory on February 21, 2022) (1) Delete some reference standards, the details are as follows: Delete: Safety and Electromagnetic Compatibility standards: a, IEC 60061-1 Specification for lamp caps and holders together with gauges for the control of interchangeability and safety-lamp caps.
b, IEC 61000-3-2 Electromagnetic compatibility (EMC)-part 3-2 Limits for harmonic current emissions (equipment current <16A per phase).
c, IEC 61195 Double-capped fluorescent lamps-Safety specifications.
d, IEC 61199 Single-capped fluorescent lamps-Safety specifications.
e, IEC 61347-1 Lamp control gear-part 1: General and Safety specifications.
f, IEC 61347-2 Particular requirements for d.c. or a.c. supplied electrical control gear for LED modules.
g, IEC 62035 Discharge lamps (excluding fluorescent lamps)-safety specifications.
h, IEC 62776 Double-capped LED lamps designed to retrofit linear fluorescent lamps Safety specifications.
(2) The technical definition has changed:Deleted: definition of decorative lamps; definition of decorative chandeliers.
(
3) Marking requirements have changed:For special-purpose lamps, it is necessary to reflect on the packaging:
Trademark, model name, rated power, rated voltage, rated luminous flux, rated color temperature, place of origin, use.
(4) Family registration requirements have changed:Use the model with the lowest performance to apply for all models, provided that:
a. Luminous flux;
b. All models are of the same type;
c. All models have the same manufacturer and the same origin;
d. All models have the same energy efficiency rating;
e. For products in the same family, the ratio of the minimum to maximum luminous flux cannot exceed 100%.
(5) Change clause B.1.2 exempted products are not for lighting purposes:Deleted: Decorative Lights Clause
ADDED: Lamps and luminaires that cannot be tested against a reference standard.
(6) Requirements for the function and durability of non-directional fluorescent lamps:Increase: allow 2000h luminous flux maintenance rate and survival rate.
(
7) Regarding non-directional and directional LED light sources and lamps:Addition: 6000-hour luminous flux maintenance rate and survival rate according to IEC 62722 or LM-84 are allowed for registration. If there is an IEC62717 or LM-80 report, it is allowed to provide the 2000-hour luminous flux maintenance rate and survival rate according to IEC 62722 or LM-84. Public number: Shenzhen LED Network
(8) Change the marking requirements for non-directional light sources and lamps:Nominal power is changed to Rated power (Watt).
(9) Packaging information requirements have changed:On the original basis, change the rated effective luminous flux to the rated luminous flux.
(10) The packaging information requirements for drivers and ballasts have been changed:Added: trademark, model name, country of origin, rated voltage and strobe, rated power efficiency, rated input power, rated power factor, rated ambient temperature and rated Tc temperature.
(11) The power efficiency requirements of control gear for halogen lamps and LED lamps have been changed:Controls for halogen lamps have a minimum power efficiency of 0.91 at full load;
(12) Change the EEI requirements for the energy efficiency level of lamps:The calculated energy efficiency level EEI is rounded to two decimal places.
(13) Changes to market random inspection criteria:There is no limit to the number of random samples.